Skip to Main Site Navigation Skip to Content Skip to Footer
Back To Top

NABC Non-Acid Disinfectant Bathroom Cleaner 7116

Spartan Chemical Company, Inc. - Material Safety Data Sheet

Section I: Product Information

Product Name: NABC NON-ACID DISINFECTANT BATHROOM CLEANER

Product Number: 7116; 7496

Product Division: Janitorial

Shipping Description: Cleaning compounds, liquid, n.o.s.

Spartan Chemical Company, Inc.
1110 Spartan Drive, Maumee, OH 43537

Product/Technical Information: 1-800-537-8990
Medical Emergency: 1-888-314-6171 (24 hours)
Chemical Leak/Spill Emergency (CHEMTREC): 1-800-424-9300 (24 hours)

NFPA Ratings:
Health: 1 - Slight
Fire: 0 - Minimal
Reactivity: 0 - Minimal

HMIS Ratings:
Health: 1 - Slight
Fire: 0 - Minimal
Reactivity: 0 - Minimal
Personal Protective Equipment: See Section VIII

Section II: Hazardous Ingredients

Listed when present at 1% or greater; carcinogens at 0.1% or greater. All component chemicals are listed or exempted from listing on the TSCA Inventory of chemical substances maintained by the U.S. Environmental Protection Agency.

Chemical Name: Isopropyl alcohol
% W: 01–05
CAS Registry No.: 67-63-0
TWA mg/m³: 980
STEL mg/m³: 1225
Ceiling mg/m³: Not Established
Carcinogen: No

Chemical Name: Nonyl phenol ethoxylate
% W: 01–05
CAS Registry No.: 9016-45-9
TWA mg/m³: Not Established
STEL mg/m³: Not Established
Ceiling mg/m³: Not Established
Carcinogen: No

Chemical Name: Dialkyl dimethyl ammonium chloride
% W: <1.0
CAS Registry No.: 68424-95-3
TWA mg/m³: Not Established
STEL mg/m³: Not Established
Ceiling mg/m³: Not Established
Carcinogen: No

Chemical Name: Alkyl dimethyl benzyl ammonium chloride
% W: <1.0
CAS Registry No.: 68424-85-1
TWA mg/m³: Not Established
STEL mg/m³: Not Established
Ceiling mg/m³: Not Established
Carcinogen: No

Section III: Physical Data

Boiling Point: 210 °F
Vapor Pressure: Unknown
Vapor Density (Air = 1): Unknown
Solubility in Water: Complete
pH: 6.0–7.0 (concentrate)
Specific Gravity (H₂O = 1): 0.995 @ 75 °F
Evaporation Rate (Butyl Acetate = 1): <1
Percent Solid by Weight: 2
Physical State: Liquid
Appearance & Odor: Blue colored liquid, floral fragrance

Section IV: Fire & Explosive Hazard Data

Flash Point: >200 °F
Method Used: ASTM-D56
Flammable Limits: N/A
Flame Extension: N/A
Extinguishing Media: N/A
Special Fire Fighting Procedures: N/A
Unusual Fire & Explosive Hazards: N/A

Section V: Health Hazard Data

Threshold Limit Value: Not Established
Primary Routes of Entry: Inhalation, Skin Contact, Eyes, and Ingestion
Effects of Overexposure / Conditions to Avoid: Causes moderate eye irritation. Harmful if absorbed through the skin. May be harmful if swallowed. Inhalation may cause respiratory irritation. Avoid contact with eyes, skin or clothing. Do not swallow. Avoid breathing product mist. Wash thoroughly with soap and water after handling.

Conditions Aggravated by Use: Preexisting skin, eye, and respiratory disorders.

Emergency & First Aid Procedures

Eyes: Hold eye open and rinse slowly and gently with water for 15–20 minutes. Remove contact lenses if present after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for treatment advice.
Skin: Take off contaminated clothing. Rinse skin immediately with plenty of water for 15–20 minutes. Call a poison control center or doctor for treatment advice.
Ingestion: Do not induce vomiting. Drink one or two glasses of water to dilute product. Call a poison control center or doctor for treatment advice. Do not give anything by mouth to an unconscious person.
Inhalation: In case of respiratory irritation, move person to fresh air. Get medical attention if irritation persists.

Section VI: Reactivity Data

Stability: Stable
Incompatible Materials: Strong oxidizers
Hazardous Decomposition Products: None
Hazardous Polymerization: Will Not Occur

Section VII: Spill or Leak Procedures

Steps if Material is Released or Spilled: Flush with water to sanitary sewer. Prevent product from contaminating streams, ponds, lakes or other bodies of water.
Waste Disposal Method: Sanitary sewer.

Section VIII: Special Protection Information

Respiratory Protection: Not usually required when good ventilation is provided. However, if exposure limits are exceeded (see Section II) or if respiratory irritation occurs, a NIOSH approved respirator should be worn.
Ventilation: Good general ventilation should be sufficient for most conditions. Local exhaust ventilation may be necessary for some operations.
Protective Gloves: Impervious gloves are recommended for frequent or prolonged contact.
Eye Protection: Splash goggles or safety glasses are recommended.
Other Protective Equipment: See 29 CFR 1910.132-138

Section IX: Special Precautions

Precautions - Handling & Storing: Keep out of reach of children.
Other Precautions: None

Document Information

© SCC 03/29/2002
Prepared by: Ronald T. Cook, Manager, Regulatory Affairs
Effective Date: 03/29/2002
Supersedes: 09/27/99
Changes: Update Sections I, II, III, IV, V, VII, VIII & IX
Reference: 29 CFR 1910.1200 (OSHA)

This document has been prepared using data from sources considered technically reliable. It does not constitute a warranty, express or implied, as to the accuracy of the information contained herein. Actual conditions of use and handling are beyond sellers control. User is responsible to evaluate all available information when using product for any particular use and to comply with all Federal, State and Local laws and regulations.