Skip to Main Site Navigation Skip to Content Skip to Footer
Back To Top

Cronaclean cw 1095

CRONATRON WELDING SYSTEMS INC - CRONACLEAN CW 1095
=======================================================
MSDS Safety Information
=======================================================
FSC: 6850
MSDS Date: 08/01/1996
MSDS Num: CGSYP
LIIN: 00N006623
Product ID: CRONACLEAN CW 1095
MFN: 02
Responsible Party
Cage: 67292
Name: CRONATRON WELDING SYSTEMS INC
Address: 651C NORTHPARK BLVD
City: CHARLOTTE NC 28216-2367
Info Phone Number: 704-598-1225
Emergency Phone Number: 303-623-5716
Preparer's Name: KEN HEARREAN
Published: Y
=======================================================
Contractor Summary
=======================================================
Cage: 67292
Name: CRONATRON WELDING SYSTEMS INC/SUB LAWSON
Address: 6510 NORTHPARK BLVD
City: CHARLOTTE NC 28216-2367
Phone: 704-598-1225
=======================================================
Ingredients
=======================================================
Name: SUP DAT: OFFICE, WASHINGTON, DC. 20402 FOR MORE DETAIL ON PREC TO BE
TAKEN DURING WELDING. FOR INDUS USE ONLY.
----------
Name: ING 6: NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL VICINITY OF
ARC WELDING, OPEN FLAME OR HOT SURFACES.
----------
Name: ING 7: HEAT AND/OR UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR
PHOSGENE (FP N).
----------
Cas: 71-55-6
RTECS #: KJ2975000
Name: ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE) (SARA 313) (CERCLA)
% Wt: >90
OSHA PEL: 350 PPM
ACGIH TLV: 350 PPM/450 STEL
EPA Rpt Qty: 1000 LBS
DOT Rpt Qty: 1000 LBS
Ozone Depleting Chemical: 1
----------
Cas: 106-88-7
RTECS #: EK3675000
Name: BUTANE, 1,2-EPOXY-; (1,2 BUTYLENE OXIDE)
% Wt: <1 OSHA PEL: N/K (FP N) ACGIH TLV: N/K (FP N) EPA Rpt Qty: 1 LB DOT Rpt Qty: 1 LB ------------------------------ Cas: 124-38-9 RTECS #: FF6400000 Name: CARBON DIOXIDE % Wt: <10 OSHA PEL: 5000 PPM ACGIH TLV: 5000 PPM/30000 STEL ------------------------------ Cas: 109-87-5 RTECS #: PA8750000 Name: METHANE, DIMETHOXY-; (DIMETHOXYMETHANE) % Wt: <1 OSHA PEL: N/K (FP N) ACGIH TLV: N/K (FP N) ------------------------------ Cas: 75-65-0 RTECS #: EO1925000 Name: TERT-BUTYL ALCOHOL (SARA 313) % Wt: <1 OSHA PEL: 100 PPM ACGIH TLV: 100 PPM ======================================================= Health Hazards Data =%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d%3d.html LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER. Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: NO Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO Effects of Exposure: ACUTE: MAY CAUSE DIZZ/NARCOSIS IN HIGH VAP CONCS. WILL CAUSE DEFAT OF SKIN. EFTS ARE REVERSIBLE. EYE & SKIN IRRIT. ASPIR HAZ IF SWALLOWED. MAY IRRITATE RESP TRACT. MAY CAUSE CARD ABNORMS. CHRONIC: LONG TERM EXPOS (YRS) TO HIGH CONCS OF VAPS MAY CAUSE LUNG, LIVER/KIDNEY DMG. SOLVS LISTED HAVE BEEN (EFTS OF OVEREXP) Explanation Of Carcinogenicity: NOT RELEVANT. Signs And Symptions Of Overexposure: HLTH HAZ: REPORTED TO AFFECT CNS. CHLOROCARBON MATLS HAVE PRODUCED SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING U SES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS (FP N). Medical Cond Aggravated By Exposure: AGGRAVATION OF PREEXISTING RESPIRATORY OR ALLERGIC CONDITIONS AND DERMATITIS OR SKIN DISORDERS MAY OCCUR IN SOME WORKERS AND MAY AGGRAVATE LUNG, KIDNEY, OR LIVER AILMENTS. First Aid: CALL FOR MED AID. EMPLOY FIRST AID TECHNIQUES REC BY AMERICAN RED CROSS. INHAL: REMOVE TO LOCATION W/FRESH AIR. GIVE OXYGEN IF NEC. SEEK MED AID. SKIN: WASH AFFECTED AREAS W/SOAP & WATER. EYES: FLUSH W/WATER FOR AT LEAST 15 MIN. SEEK MED AI D. INGEST: GIVE LGE QTYS OF WATER/MILK TO DILUTE. DO NOT INDUCE VOMIT. GASTRIC LAVAGE. SEEK MED AID. NEVER GIVE ANYTHING BY MOUTH TO AN UNCON PERSON. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: REMOVE SOURCES OF HEAT/IGNITION. WIPE UP SPILLED PRODUCTS W/A RAG/USE ABSORBENT SWEEPING COMPOUND & WASH AREA DOWN W/SOAP & WATER. DISPOSE OF RESIDUE IN SEALED CONTAINERS. KEEP AIRBORNE DUST AT A MINIMUM WHEN CLEANING UP. AVOID INHALATION O F DUST. Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER. Waste Disposal Methods: PREVENT WASTE FROM CONTAMINATING SURROUNDING ENVIRONMENT. DISCARD ANY PROD, RESIDUE, DISPOSABLE CONTAINER/LINER IN ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL COMPLIANCE W/FED, STATE & LOC REGULATIONS. DO NOT PUNCTURE/INCINERATE AEROSOL CONT AINERS. Handling And Storage Precautions: STORE IN COOL, DRY PLACE, AVOIDING CONT W/EXTREME HEAT/COLD TO MAINTAIN PROD QUALITY. AVOID CONT W/EYES, SKIN/CLTHG. KEEP OUT OF REACH OF CHILDREN. Other Precautions: USE GOOD HOUSEKEEPING PRACT TO PVNT ACCUMS OFDUST/FUMES. DO NOT SMOKE, EAT/DRINK IN WORK AREA. VAPS MAY COLLECT IN LOWLYING AREAS. READ & UNDERSTAND MFR'S INSTRUCTIONS & PREC LABEL ON PROD. SEEAMERICAN NATIONAL STD Z49.1, (SUP DAT) ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Text: NOT FLAMMABLE Extinguishing Media: DRY CHEMICAL, WATER FOG, FOAM, CARBON DIOXIDE. Fire Fighting Procedures: WEAR NIOSH APPRVD PRESS DEMAND SCBA & FULL PROT EQUIP (FP N). WATER STREAM DIRECTED INTO FIRE MAY CAUSE FROTHING W/SUBSEQUENT SPREAD OF FLAME. (SUP DAT) Unusual Fire/Explosion Hazard: AEROSOL PRODUCTS UNDER PRESSURE. EXPOSURE TO TEMPERATURES ABOVE 120F MAY CAUSE BURSTING. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL AND PHOSGENE (FP N). ======================================================= Control Measures ======================================================= Respiratory Protection: USE NIOSH APPROVED RESPIRABLE VAPOR RESPIRATOR/AIR SUPPLIED RESP WHEN USING PRODUCTS, OR NIOSH APPROVED FUME/DUST RESPIRATOR WHEN WELDING, BRAZING/SOLDERING IN CONFINED SPACE/WHERE LOCAL EXHAUST/VENTILATION DOES NOT KEEP EXPOSURE BELOW TLV. Ventilation: USE ENOUGH VENT, LOC EXHAUST/BOTH AT WORK AREA TO KEEP FUMES & GASES BELOW TLV IN WORKER'S BRTHG ZONE & GENERAL AREA. Protective Gloves: CHEMICAL-RESISTANT GLOVES. Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N). Other Protective Equipment: EMERGENCY EYEWASH AND DELUGE SHOWER MEETING ANSI DESIGN CRITERIA (FP N). USE CHEMICAL-RESISTANT APRONS. Work Hygienic Practices: WASH HANDS AFTER HANDLING. Supplemental Safety and Health: FIRE FIGHT PROC: WATER FOG MAY BE USED TO COOL CLSD CONTRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT. OTHER PREC: SFTY IN WELDING & CUTTING, PUBLISHED BY AMERICAN WELDING SOCIETY, P.O. BOX 351040, MIAMI, FL 33135 & OSHA PUBLICATION 2206 (29 CFR 1910), US GOVERNMENT PRINTING ======================================================= Physical/Chemical Properties ======================================================= B.P. Text: >162F,>72C
Vapor Pres: 100
Vapor Density: 4.0
Spec Gravity: 1.3 (H*2O=1)
Evaporation Rate & Reference: >1 (BUTYL ACETATE=1)
Solubility in Water: NONE
Appearance and Odor: CLEAR SPRAY WITH ETHEREAL ODOR
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: EXPOSURE TO HIGH TEMPERATURES SHOULD BE AVOIDED.
Materials To Avoid: AVOID CONTACT WITH STRONG OXIDIZERS AND ACTIVE METALS.
Hazardous Decomposition Products: DECOMPOSITION PRODUCTS INCLUDE CARBON
DIOXIDE, HALOGEN ACIDS AND PHOSGENE. HCL (FP N).
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
Product ID: CRONACLEAN CW 1095
Cage: 67292
Company Name: CRONATRON WELDING SYSTEMS INC/SUB LAWSON
Street: 6510 NORTHPARK BLVD
City: CHARLOTTE NC
Zipcode: 28216-2367
Health Emergency Phone: 303-623-5716
Label Required IND: Y
Date Of Label Review: 03/27/1998
Status Code: C
Label Date: 03/27/1998
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: None
Reactivity Hazard: Slight
Hazard And Precautions: DECOMPOSITION PRODUCTS MAY BE HAZARDOUS. ACUTE:
INHALATION OF VAPORS MAY CONTRIBUTE TO THE OCCURRENCE OF IRREGULAR HEARTBEAT
(FP N). MAY CAUSE DIZZINESS OR NARCOSIS IN HIGH VAPOR CONCENTRATIONS. WILL
CAUSE DEFATTING OF SKIN. EFFECTS ARE REV ERSIBLE. EYE AND SKIN IRRITATION.
ASPIRATION HAZARD IF SWALLOWED. MAY IRRITATE RESPIRATORY TRACT. MAY CAUSE
CARDIAC ABNORMALITIES. CHRONIC: LONG TERM EXPOSURE (YEARS) TO HIGH
CONCENTRATIONS OF VAPORS MAY CAUSE LUNG, LIVER OR KIDNEY DAMAGE. SOLVENTS
LISTED HAVE BEEN REPORTED TO AFFECT THE CENTRAL NERVOUS SYSTEM.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.